Gas Turbine Generator — GE LM2500 Base & Acoustic Enclosure
−20dB
Sound power ↓
15%
Vibration ↓
20%
Space usage ↓
>5%
Above DVP&R margin
A GE LM2500 gas turbine generator package requires a fully integrated base structure and acoustic enclosure meeting strict GE safety, noise, and structural compliance.
Design the mechanical base-structure and acoustic enclosure to GE specification while maximizing space efficiency and NVH performance.
Created BOQ, assembly, and fabrication drawings in SolidWorks per ASME Y14.5. Designed sheet-metal base and acoustic enclosure with efficient shock mounts. Performed static and dynamic FEA for NVH characterization. Integrated exhaust system with sensor and DAQ provisions.
Reduced constrained space usage by 20% without compromising access. Achieved −20 dB sound power reduction. Cut transmitted vibration by 15% via shock mounts. Structural margin > 5% above DVP&R spec. System passed GE compliance review at first submission.